INSTALLATION MANUAL
Models:
CH-18MSPH-230VO
CH-28MSPH-230VO
CH-36MSPH-230VO
CH-48MSPH-230VO
IMPORTANT NOTE:
Read this manual carefully before
installing or operating your new air
conditioning unit. Make sure to save
this manual for future reference.
This manual only describes the installation of
the outdoor unit. When installing the indoor unit,
refer to the installation manual of the indoor unit.
MULTI-ZONE
INVERTER
SOPHIA
SPLIT AIR CONDITIONER
WITH HEAT PUMP
OUTDOOR UNIT
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - MULTI-ZONE

INSTALLATION MANUALModels:CH-18MSPH-230VOCH-28MSPH-230VOCH-36MSPH-230VOCH-48MSPH-230VOIMPORTANT NOTE:Read this manual carefully before installing or o

Pagina 2 - Table of Contents

 Page 10 Table 6.1: Length Specications of Split Type Outdoor Unit (unit: inch/mm) Split Type Outdoor Unit(Refer to Fig 6.4, 6.5, 6.6, 6.10, and T

Pagina 3 - A. Evacuation Instructions

 Page 11 Outdoor Unit InstallationWhen Selecting a 24K Indoor UnitThe 24K indoor unit can only be connected with anA system. If there are two 24K i

Pagina 4 - Accessories

 Page 12 Refrigerant Piping Connection7Safety Precautions WARNING• All eld piping must be completed by a licensed technician and must comply with

Pagina 5 - Safety Precautions

 Page 13 4. Remove the PVC tape from the ends of the pipe when you're ready to perform the aring work. 5. Clamp the are form on the end of t

Pagina 6 - Installation Overview

WiringSafety Precautions WARNING• Be sure to disconnect the power supply before working on the unit. • All electrical wiring must be done according

Pagina 7 - Installation Diagram

Table 8.2: Other RegionsRated Current of Appliance (A)Nominal Cross-Sectional Area (mm²)≤ 6 0.756 - 10 110 - 16 1.516 - 25 2.525 - 32 432 - 45 6 P

Pagina 8 - Specications

 Page 16 Wiring FigureWiringNOTE: If the client wants to perform the wiring himself, refer to the following gures. Run the main power cord through

Pagina 9 - Outdoor Unit Installation

 Page 17 WiringNOTE: If the client wants to perform the wiring himself, refer to the following gures.One-three models:One-four models:Model A Mode

Pagina 10 -  Page 10 

 Page 18 WiringOne-ve models:Model A Model BModel C Model DModel EModel FModel G

Pagina 11 - Installation

CAUTIONAfter the conrmation of the above conditions, prepare the wiring as follows: • Never fail to delegate an individual power circuit specicall

Pagina 12 - Refrigerant Piping Connection

Accessories ...04Safety Precautions ...

Pagina 13 - CAUTION

Fig. 9.3 Page 20 Air Evacuation9Safety PrecautionsEvacuation Instructions Before using the manifold gauge or vacuum pump, read their operation manu

Pagina 14 - WARNING

 Page 21 Note on Adding RefrigerantSafety And Leakage Check CAUTION• Refrigerant charging must be performed after wiring, vacuuming, and the leak

Pagina 15 -  Page 15 

 Page 22 Test Run Before Test RunA test run must be performed after the entire system has been completely installed. Confirm the following points be

Pagina 16

Automatic Wiring/Piping Correction Function Page 23 Function of Automatic Wiring/Piping Correction 11The new product is able to automatically corre

Pagina 17 -  Page 17 

The design and specications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for de

Pagina 18 -  Page 18 

 Page 3 Refrigerant Piping Connection ... 12Wiring ...14 A. Outdoor U

Pagina 19

 Page 4 Accessories1The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install

Pagina 20 - Air Evacuation

 Page 5 Safety Precautions2Read safety precautions before installationIncorrect installation due to ignoring instructions can cause serious damage

Pagina 21

 Page 6 Installation Overview3Unit Installation OverviewL N123MC MC45INSTALLATION ORDERInstall the outdoor unit(Page 9)Evacuate the refrigeration s

Pagina 22 - Test Run

 Page 7 Installation Diagram4Installation DiagramFig. 4.1Safety Precautions CAUTION• This illustration is for explanation purposes only. The actua

Pagina 23 - Correction Function

Table 5.1Table 5.2 Page 8 Specications5Outdoor Unit SpecicationsIndoor units that can be used in combinationNumber of connected units1-5 unitsCom

Pagina 24

 Page 9 Outdoor Unit InstallationOutdoor Unit InstallationOutdoor Unit Installation InstructionsStep 1: Select installation locationWhen choosing a